Antibody drug conjugates (ADCs) belong to a class of drugs featuring a monoclonal antibody...Read More
Come see us at HPLC! Table 9
Our resources accessed from the list below give a flavor of the variety of liquid chromatography analyses that can be addressed using the Axcend Focus LC®.
Abstract This application note demonstrates the use of the compact Axcend Focus LC® capillary chromatograph coupled to an Agilent Ultivo triple quadrupole mass spectrometer for quantitative analysis...
Read MoreThe Axcend Focus LC® (a compact capillary liquid chromatograph) has been successfully used for quantitative analysis of two representative biocides: 4,5-dichloro-2-n-octylisothiazolin-3-one (DCOIT)...
Read MoreThis application note demonstrates the use of the Axcend Focus LC® (AFLC) for point-of-care analysis of drugs of abuse in clinical settings such as treatment facilities and pain clinics. Traditional...
Read MoreA simple analysis of caffeine and benzoic acid in soft drinks using the compact Axcend Focus LC® is demonstrated. Linear regression of the calibration data gave R2 values of 0.9993 and 0.9998 for...
Read MoreIntroduction With on-column UV detection in packed capillary HPLC the analysis of low levels of analytes is challenging because of the short path length of the detector. Columns installed in the...
Read MoreThis application note demonstrates the use of the hand-portable Axcend Focus LC® system for intact protein analysis using reversed-phase liquid chromatography (RPLC). A mixture of five proteins...
Read MoreThe Axcend Focus LC® High-Performance Liquid Chromatography system (HPLC) delivers repeatable analyses of Active Pharmaceutical Ingredient (API) dissolution. In this test, an Extra Strength Excedrin...
Read MoreThis application note demonstrates the ability of the Axcend Focus LC® portable High-Performance Liquid Chromatography system (HPLC) to detect and separate 5 principal cannabinoids present in 50 mg...
Read MoreThe Axcend Focus LC® was used to separate polycyclic aromatic hydrocarbons (PAHs) in ~12 and ~15 minutes, respectively, with separate methods on short (10 cm x 150 µm i.d.) capillary columns packed...
Read MoreOverview Five cannabinoids* were separated and detect-ed in ~nine minutes using the Axcend FocusLC® High-Performance Liquid Chromatography system (HPLC): Cannabidiolic Acid, Cannabidi-ol, Cannabinol,...
Read MoreExperience Axcend technology firsthand and see how the fastest real-time monitoring and smallest footprint in the industry can make an impact on your workflow.
Have questions?
Get in touch with our team now.
Find us at Riva 2026, the combined 44th International Symposium on Capillary Chromatography and...
Read More